    • Application Area: It is a respiratory ventilator intended for use in emergency situations, first aid, and patient transport.
    • Patient Type: It is suitable for use in adults, children, and infants, excluding newborns.
    • Ventilation Modes: It features AUT-AST (Automatic Assist), PSV (Pressure Support Ventilation), Apnea Backup, and CPAP/PEEP modes.
    • Pressure Control: It allows adjustment of the maximum applied pressure within a range of 0 to 50 cmH₂O (Pressure Limit).
    • Respiratory Rate (RATE): The respiratory rate can be adjusted between 5 and 70 bpm.
    • Minute Volume: It determines the amount of oxygen delivered to the patient per minute, adjustable between 1 and 16 L/min (Minute Volume).
    • Tidal Volume Calculation: Minute Volume is calculated as Respiratory Rate per Minute multiplied by Tidal Volume (e.g., Infant: 12 ml/kg, Adult: 8 ml/kg).
    • Oxygen Mixer (MIXER): It can be set to 50% or 100%.
    • Battery Life: It can operate continuously for at least 4.5 hours with a fully charged internal battery.
    • External Power Supply: It can be powered by 12 VDC or via a 100–240 VAC 50 Hz adapter.
    • Operating Temperature: It can operate within a temperature range of -18 °C to +60 °C.
    • Gas Pressure Requirement: For proper operation, a pressure between 2.7 and 6 bar must be applied (oxygen or compressed medical air).
    • Apnea Protection: In PSV mode, if the patient does not breathe for 20 seconds, the device automatically switches to AUT-AST mode.
    • Alarms: It is equipped with audible and LED alarm systems for conditions such as low/high airway pressure, apnea, gas supply failure, low battery, and power failure.
    • Dimensions: It has dimensions of 186 mm in width, 132 mm in height, and 125 mm in depth.

Features Description
ApplicationEmergency / First Aid / Patient Transport 
Patient Type Adult / Child / Infant (excluding newborn)
Ventilation Type IPPV Volumetric - Pressure Supported IPPV - Time
Control Method Electronic cycling
Gas Source Oxygen or Pressurized Medical Air
Gas PressureMax. (2.7 bar- 6 bar) Range 
Flow Rate  50 L / min (max.) 
Ventilation Modes AUT-AST, PSV, Apnea Backup, CPAP and PEEP
Measurement Parameters Instant Airway Pressure
Breathing Rate 5-70 bpm
I:E Ratio  1:1.5
IInspiratory Ratio 40% of the duty cycle
nspiratory Pressure Automatic PSV Mode
Pressure Limit 0 – 50 cmH2O Range
Minute Volume -16 L/min
Tidal Volume 15-3000 ml
Oxygen Mixer %50 O2 / %100 O2 
Manometer Digital
Trigger Sensitivity 1-5 cmH2O Range
 User Interface Digital Manometer, LED Battery Level and External Power Source Interruption Indicator, LED/Audible Alarms, Control and Adjustment Buttons
 Warnings Battery Level, Low and High Airway Pressure, Apnea, Gas Source, Power Interruption
Power Supply 12VDC or 12VDC Adapter with 100-240VAC 50 Hz
 Current Consumption 20 mA (Idle) / 300 mA (Under Load)
 Battery Support 4.5 Hours Continuous Operation
 Charging Time 10 Hours Charging Time when Fully Empty
 Device Safety Adjustable Air Pressure Mechanical Limit: 0-50 cmH2O
 Dimensions and Weight Width: 186 mm Height: 132 mm Depth:125 mm
 Operating Temperature -18 °C to 60 °C
 Storage Temperature -40 °C to 70 °C
 Operating Humidity 10% to 90% Relative Humidity (Non-condensing)
 Atmospheric Pressure Range 70 kPa to 110 kPa
 Product Life 5 Years
 Alarm Level 60 db(A)
 Standard Accessories 220 V AC (50 Hz) – 12 V DC Adapter and Connection Cable, 12 V DC Vehicle Charging Connection Cable, Disposable Adult and Child Mask, Bacteria Filter, Test Balloon, Disposable PVC Patient Circuit and Expiratory Side, Oxygen Hose Carrying Strap, Ambulance Connection Kit, User Manual
 Optional Accessories Protection Kit and Bag, Oxygen Cylinder (Aluminum/Steel), Double Manometer O2 Regulator, Reusable Patient Circuit, Capnograph